QSL9, QSL9-G5
Cummins
1-7 days
Genuine Original package or Ne
1 years
Availability: | |
---|---|
Quantity: | |
PDF Export | |
Small Tips for Quick Service:
If you need assistance with selecting the right replacement parts for your engine, please contact our ONLINE SERVICE to get fast customer support.
For us to provide you with the correct information, please have your Cummins Engine Part Number or Engine Serial Number ready, so that we can give you the best price possible along with our expertise.
Generator set specifications
Governor regulation class | ISO8528 G3 for C300/330 D5/e, C275/300 D6/e ISO8528 G2 for C250/275 D5/e, C230/250 D6/e |
Voltage regulation, no load to full load | ± 1% |
Random voltage variation | ± 1% |
Frequency regulation | Isochronous |
Random frequency variation | ± 0.5% |
EMC compatibility | BS EN61000-6-4 / BS EN61000-6-2 |
Engine specifications
Design | 4 cycle, in-line, turbocharged, charge air-cooled |
Bore | 114 mm (4.5 in.) |
Stroke | 145 mm (5.7 in.) |
Displacement | 8.8 liter (543 in3) |
Cylinder block | Cast iron, 6 cylinder |
Battery capacity | 100 AH |
Battery charging alternator | 70 amps |
Starting voltage | 24 volt, negative ground |
Fuel system | Direct injection |
Fuel filter | Spin on fuel filters with water separator, StrataPore™ technology, extended life |
Air cleaner type | Heavy duty, dry replaceable element, OptiAir™ technology, 2-stage air filters |
Lube oil filter type(s) | Spin on full flow filter, StrataPore technology, extended life |
Standard cooling system | 122 °F (50 °C) ambient radiator for QSL9-G5 powered sets 105 °F (40 °C) ambient radiator for QSL9-G7 powered sets |
Alternator specifications
Design | Brushless, single bearing, revolving field |
Stator | 2/3 pitch |
Rotor | Single bearing, flexible disc |
Insulation system | Class H |
Standard temperature rise | Prime 125 ºC temp rise @ 40 ºC ambient Standby 163 ºC temp rise @ 27 ºC ambient |
Exciter type | Self excited or separately excited by PMG |
Phase rotation | A (U), B (V), C (W) |
Alternator cooling | Direct drive centrifugal blower fan |
AC waveform Total Harmonic Distortion (THDV) | No load <1.5%. Non distorting balanced linear load <5% |
Telephone Influence Factor (TIF) | < 50% per NEMA MG1-122.43 |
Telephone Harmonic Factor (THF) | <2% |
CONFIGURATIONS AND MODEL NAMES | |
EPA Model Name | Not Available |
---|---|
Marketing Engine Configuration # | D563007GD03 |
Marketing Model Name | QSL8.8-G5 |
Service Model Name | QSL9 CM850(CM2850) |
Technical Engine Configuration # | D563007GX03 |
ENGINE BUILD DETAILS | |
Build Date | 2010-09-08T00:00:00Z |
Build Plant | DAR - DARLINGTON OPERATIONS |
CPL # | 8693 |
Shop Order | SO7890 |
Warranty Start Date | Not Available |
TECHNICAL SPECIFICATION DETAILS | |
ECM Code | Not Available |
Fuel Pump Part # | 4921431 |
Fuel Pump Calibration | Not Available |
Cummins Power Generation rental generator set is a fully integrated power generation system providing optimum performance, reliability and versatility for stationary standby and prime power applications.
Genset model |
Engine model | Standby rating | Prime rating | Emissions compliance | Data sheets | |||
50 Hz kVA (kWe) | 60 Hz kWe (kVA) | 50 Hz kVA (kWe) | 60 Hz kWe (kVA) | TA Luft/ EU Stage/EPA | 50 Hz | 60 Hz | ||
C275 D5 | QSL9-G5 | 275 (220) | 250 (200) | 4g TA Luft | DS22-CPGK | |||
C300 D5 | QSL9-G5 | 300 (240) | 275 (220) | 4g TA Luft | DS23-CPGK | |||
C330 D5 | QSL9-G5 | 330 (264) | 300 (240) | 4g TA Luft | DS24-CPGK | |||
C250 D6 | QSL9-G5 | 250 (313) | 225 (282) | DS69-CPGK | ||||
C275 D6 | QSL9-G5 | 275 (344) | 250 (313) | DS70-CPGK | ||||
C300 D6 | QSL9-G5 | 300 (375) | 275 (344) | DS71-CPGK | ||||
C250 D5e | QSL9-G7 | 250 (200) | 230 (184) | EU SIII A | EMERD-6136 | |||
C275 D5e | QSL9-G7 | 275 (220) | 250 (200) | EU SIII A | EMERD-6137 | |||
C300 D5e | QSL9-G7 | 300 (240) | 275 (220) | EU SIII A | EMERD-6138 | |||
C330 D5e | QSL9-G7 | 330 (264) | 300 (240) | EU SIII A | EMERD-6139 | |||
C230 D6e | QSL9-G7 | 230 (288) | 207 (259) | EPA T3 | EMERD-6140 | |||
C250 D6e | QSL9-G7 | 250 (313) | 225 (282) | EPA T3 | EMERD-6141 | |||
C275 D6e | QSL9-G7 | 275 (344) | 250 (313) | EPA T3 | EMERD-6142 | |||
C300 D6e | QSL9-G7 | 300 (375) | 275 (344) | EPA T3 | EMERD-6143 |
Small Tips for Quick Service:
If you need assistance with selecting the right replacement parts for your engine, please contact our ONLINE SERVICE to get fast customer support.
For us to provide you with the correct information, please have your Cummins Engine Part Number or Engine Serial Number ready, so that we can give you the best price possible along with our expertise.
Generator set specifications
Governor regulation class | ISO8528 G3 for C300/330 D5/e, C275/300 D6/e ISO8528 G2 for C250/275 D5/e, C230/250 D6/e |
Voltage regulation, no load to full load | ± 1% |
Random voltage variation | ± 1% |
Frequency regulation | Isochronous |
Random frequency variation | ± 0.5% |
EMC compatibility | BS EN61000-6-4 / BS EN61000-6-2 |
Engine specifications
Design | 4 cycle, in-line, turbocharged, charge air-cooled |
Bore | 114 mm (4.5 in.) |
Stroke | 145 mm (5.7 in.) |
Displacement | 8.8 liter (543 in3) |
Cylinder block | Cast iron, 6 cylinder |
Battery capacity | 100 AH |
Battery charging alternator | 70 amps |
Starting voltage | 24 volt, negative ground |
Fuel system | Direct injection |
Fuel filter | Spin on fuel filters with water separator, StrataPore™ technology, extended life |
Air cleaner type | Heavy duty, dry replaceable element, OptiAir™ technology, 2-stage air filters |
Lube oil filter type(s) | Spin on full flow filter, StrataPore technology, extended life |
Standard cooling system | 122 °F (50 °C) ambient radiator for QSL9-G5 powered sets 105 °F (40 °C) ambient radiator for QSL9-G7 powered sets |
Alternator specifications
Design | Brushless, single bearing, revolving field |
Stator | 2/3 pitch |
Rotor | Single bearing, flexible disc |
Insulation system | Class H |
Standard temperature rise | Prime 125 ºC temp rise @ 40 ºC ambient Standby 163 ºC temp rise @ 27 ºC ambient |
Exciter type | Self excited or separately excited by PMG |
Phase rotation | A (U), B (V), C (W) |
Alternator cooling | Direct drive centrifugal blower fan |
AC waveform Total Harmonic Distortion (THDV) | No load <1.5%. Non distorting balanced linear load <5% |
Telephone Influence Factor (TIF) | < 50% per NEMA MG1-122.43 |
Telephone Harmonic Factor (THF) | <2% |
CONFIGURATIONS AND MODEL NAMES | |
EPA Model Name | Not Available |
---|---|
Marketing Engine Configuration # | D563007GD03 |
Marketing Model Name | QSL8.8-G5 |
Service Model Name | QSL9 CM850(CM2850) |
Technical Engine Configuration # | D563007GX03 |
ENGINE BUILD DETAILS | |
Build Date | 2010-09-08T00:00:00Z |
Build Plant | DAR - DARLINGTON OPERATIONS |
CPL # | 8693 |
Shop Order | SO7890 |
Warranty Start Date | Not Available |
TECHNICAL SPECIFICATION DETAILS | |
ECM Code | Not Available |
Fuel Pump Part # | 4921431 |
Fuel Pump Calibration | Not Available |
Cummins Power Generation rental generator set is a fully integrated power generation system providing optimum performance, reliability and versatility for stationary standby and prime power applications.
Genset model |
Engine model | Standby rating | Prime rating | Emissions compliance | Data sheets | |||
50 Hz kVA (kWe) | 60 Hz kWe (kVA) | 50 Hz kVA (kWe) | 60 Hz kWe (kVA) | TA Luft/ EU Stage/EPA | 50 Hz | 60 Hz | ||
C275 D5 | QSL9-G5 | 275 (220) | 250 (200) | 4g TA Luft | DS22-CPGK | |||
C300 D5 | QSL9-G5 | 300 (240) | 275 (220) | 4g TA Luft | DS23-CPGK | |||
C330 D5 | QSL9-G5 | 330 (264) | 300 (240) | 4g TA Luft | DS24-CPGK | |||
C250 D6 | QSL9-G5 | 250 (313) | 225 (282) | DS69-CPGK | ||||
C275 D6 | QSL9-G5 | 275 (344) | 250 (313) | DS70-CPGK | ||||
C300 D6 | QSL9-G5 | 300 (375) | 275 (344) | DS71-CPGK | ||||
C250 D5e | QSL9-G7 | 250 (200) | 230 (184) | EU SIII A | EMERD-6136 | |||
C275 D5e | QSL9-G7 | 275 (220) | 250 (200) | EU SIII A | EMERD-6137 | |||
C300 D5e | QSL9-G7 | 300 (240) | 275 (220) | EU SIII A | EMERD-6138 | |||
C330 D5e | QSL9-G7 | 330 (264) | 300 (240) | EU SIII A | EMERD-6139 | |||
C230 D6e | QSL9-G7 | 230 (288) | 207 (259) | EPA T3 | EMERD-6140 | |||
C250 D6e | QSL9-G7 | 250 (313) | 225 (282) | EPA T3 | EMERD-6141 | |||
C275 D6e | QSL9-G7 | 275 (344) | 250 (313) | EPA T3 | EMERD-6142 | |||
C300 D6e | QSL9-G7 | 300 (375) | 275 (344) | EPA T3 | EMERD-6143 |